FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems

Product Details
Media: Water
Driving Mode: Manual
Connection Form: Groove End
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Type of Ownership
Private Owner
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
  • FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2" to 12", for Fire Sprinkler Systems
Find Similar Products
  • Overview
  • Product Description
  • Application
  • Installation Note
  • Detailed Photos
  • Packaging & Shipping
  • Certifications
  • Company Profile
  • Why Choose Us
Overview

Basic Info.

Model NO.
ACV-300GE
Structure
Centre Sealing
Seal Form
Supercharging Pressured Sealed
Valve Stem
Normal
Work Pressure
Mid-Pressure (2.5mpa< Pn <6.4mpa)
Working Temperature
4-70ºC
Material of Seal Surface
Soft Sealed
Valve Body
Casting
Standard
ANSI or DIN
Application
Industrial Usage
Certificates
FM/UL
Surface
Epoxy Coated or Coating Upon Request
Color
Red or Others
Maximum Working Pressure
300 Psi
Maximum Testing Pressure
600 Psi
Quality
High Quality
Transport Package
Wooden Box
Specification
2" to 12"
Trademark
FIS or Others
Origin
China
HS Code
8481804090

Product Description

Product Description

 

FM/UL Certified Wet Alarm Check Valve - Flange & Groove End 

Elite Fire Equipment Co., Ltd produce high quality fire fighting FM/UL certified Valves(Butterfly Valves, Gate valves, Check Valves, Alarm Check Valves, Deluge Valves, Air Release Valves, Landing Valves, etc), Hydrants, Malleable Iron Pipe Fittings, Couplings and Fittings,Fire Pipes & Hangers, Sprinklers and Accessories, Fire Extinguishers & Fire Blankets.

Elite Fire wet alarm check valve consists of wet alarm valve, retard chamber, pressure gauges, water motor alarm, pressure switch, drain valve and filter etc.


Wet Type Grooved Alarm Check Valve
Technical Features

·Certificates: FM, UL
·Sizes: 2"-12" 
·Groove Standard: AWWA C606
                                  ISO6182-12
·Working Pressure: 300PSI(20.7 Bar)
·Working Temperature: 4~70°C /39.2~158°F
·Coating Details: Epoxy Coating or Coating Upon Requests.



Product Overview:
The FM/UL Certified Alarm Check Valve is a critical fire sprinkler system component designed to prevent backflow while triggering waterflow alarms during activation. Available in flange and grooved end configurations, this heavy-duty valve meets FM Global (FM) and Underwriters Laboratories (UL) standards, ensuring compliance with NFPA 13, 14, and 72 for commercial and industrial fire protection.


Alarm Check Valves act as a water flowalarm initiating device in wet pipe sprinkler systems. When waterflows in the sprinkler system due to the operation of one or more automatic fire sprinklers, the alarm valve opens allowing continuous flow of water into the system, which will activate water motor bell and pressure switches.
The design of the Alarm Check Valve alows for installation under both variable and constant supply pressure conditions. The valve trim incorporates a bypass between the water supply and the wet pipe system. When pressure surges in the waters supply occur, the trim allows a small amount of water to bypass the clapper limiting the potential of false alarms.

 

Application


1. Wet pipe fire sprinkler systems
2. Industrial fire protection networks
3. High-rise building standpipes
4. Water storage tank supply lines

This system is applicable to the places with the ambient temperature from 4°C to 70°C. This system is generally installed in the places with fire hazards, like the hotel, shopping mall, hospital, theater, office building, conference center, warehouse,high-rise building and underground garage.

 

Installation Note

This instrument shall be installed in places where is easy to observe and access.Install The wet alarm valve vertically on the pipes which have been properly tested for its pressure and cleaned. Please note that the arrow for water flow direction is pointing upwards. Reserve enough operation space for repair and maintenance before installation.
Step1: Clean the system pipe network completely before installation. Ensure that the inner wall of the pipes is coated with rust-proof layer and there is no dreg or dirt in the pipes.
Step2: In order to facilitate the observation of the pipe in which an alarm occurs, it is recommended to discharge the water from an open port or have the water discharge state easy to be observed before installation.
Step3: Check whether there is any damage at the joint between the wet alarm valve and the flange, check whether the seal is in good condition and whether the valve disc moves flexibly, carry out the leakage test with a pressure of two times of the rated working pressure.After the test, the valve disc shall be free of leakage;If there is any problem, replace the spare parts or clear the trouble before assembling the parts together.

 
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems

Available Sizes
 
 
 
SIZE DN
2" DN50
2-1/2" DN65
3" DN80
4" DN100
5" DN125
6" DN150
8" DN200
10" DN250
12" DN300
 

Detailed Photos

 

FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
 
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems

 

 

  

Packaging & Shipping

 

FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems

Certifications

FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems
FM/UL Certified Wet Alarm Check Valve - Grooved Ends, 2&quot; to 12&quot;, for Fire Sprinkler Systems

 

 

Company Profile

Established in 2019, Elite Fire Equipment Co., Ltd is a specialized company dedicated to providing high-quality fire protection products worldwide. With a strong commitment to safety, reliability, and innovation, we serve distributors, contractors, and industrial clients across the globe.
Our Product Range:
We supply a comprehensive selection of certified firefighting equipment, including:

  • Fire Valves & Accessories
  • Malleable Iron Pipe Fittings
  • Couplings and fittings
  • Fire Extinguishers & Fire Blankets
  • Fire Pipes & Hangers
  • Sprinklers and Accessories
  • Dry and Wet Hydrant
All our products meet stringent international standards and hold prestigious certifications such as FM, UL, LPCB, KITE MARK, ensuring compliance with global safety regulations.
At 
Elite Fire, we don't just sell products-we deliver trusted fire safety solutions. Partner with us to safeguard lives and properties with equipment that meets the highest standards.
 

Why Choose Us

Globally Recognized Certifications - Assurance of performance and reliability.
 End-to-End Solutions - From valves to hydrants, pipes to fittings, extinguishers to sprinklers, we cover your fire safety needs.
 Efficient Global Logistics - Timely delivery to over 100 countries and regions all over the world.
 Technical Expertise - Dedicated support for product selection and customization.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier